Low Voltage 3 phase 4 wire electrical power cables YJV YJLV copper aluminum conductor XLPE/PVC insulated armoured Underground cable for electricity supply



600/1000V, PVC Insulated Cables according to IEC 60502-1
Applications
These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.
Construction
Conductors
The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
Insulation
PVC Insulation material and thickness shall be as per IEC 60502-1, PVC material shall be Type A as per IEC 60502-1.
Colour Code
Colour Code (1)
1 Core |
Red or Black |
2 Cores |
Red, Black |
3 Cores |
Red, Yellow, Blue |
4 Cores |
Red, Yellow, Blue, Black |
5 Cores |
Red, Yellow, Blue, Black, Green |
Above 5 Cores |
Black Cores with White numerals |
Colour Code (2)
1 Core |
Brown or Blue |
2 Cores |
Brown, Blue |
3 Cores |
Brown, Black, Grey |
4 Cores |
Blue, Brown, Black, Grey |
5 Cores |
Green/Yellow, Blue, Brown, Black, Grey |
Above 5 Cores |
Black Cores with White numerals |
Other colours can be manufactured upon request.
Assembly / Inner Covering
The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
Armour
Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
Outer Sheath
Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
Fire Performance of Cable Sheaths
Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.
Parameters
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Overall Diameter (Approx.) |
mm^2 |
mm |
mm |
mm |
mm |
1x4 |
2.3 |
1 |
1.4 |
7.1 |
1x6 |
2.8 |
1 |
1.4 |
7.6 |
1x10 |
3.6 |
1 |
1.4 |
8.4 |
1x16 |
4.5 |
1 |
1.4 |
9.3 |
1x25 |
5.6 |
1.2 |
1.4 |
10.8 |
1x35 |
6.7 |
1.2 |
1.4 |
11.9 |
1x50 |
8 |
1.4 |
1.4 |
13.6 |
1x70 |
9.4 |
1.4 |
1.4 |
15.1 |
1x95 |
11 |
1.6 |
1.5 |
17.2 |
1x120 |
12.4 |
1.6 |
1.5 |
18.7 |
1x150 |
13.8 |
1.8 |
1.6 |
20.6 |
1x185 |
15.3 |
2 |
1.7 |
22.7 |
1x240 |
17.5 |
2.2 |
1.8 |
25.4 |
1x300 |
19.5 |
2.4 |
1.9 |
28.0 |
1x400 |
22.6 |
2.6 |
2.0 |
31.7 |
1x500 |
25.2 |
2.8 |
2.1 |
35.0 |
1x630 |
28.3 |
2.8 |
2.2 |
38.3 |
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Overall Diameter (Approx.) |
mm^2 |
mm |
mm |
mm |
mm |
2x1.5 |
1.4 |
0.8 |
1.8 |
9.6 |
2x2.5 |
1.8 |
0.8 |
1.8 |
10.4 |
2x4 |
2.3 |
1 |
1.8 |
12.2 |
2x6 |
2.8 |
1 |
1.8 |
13.2 |
2x10 |
3.6 |
1 |
1.8 |
14.8 |
2x16 |
4.5 |
1 |
1.8 |
16.6 |
2x25 |
5.6 |
1.2 |
1.8 |
19.6 |
2x35 |
6.7 |
1.2 |
1.8 |
21.8 |
2x50 |
8 |
1.4 |
1.8 |
25.2 |
2x70 |
9.4 |
1.4 |
1.9 |
28.1 |
2x95 |
11 |
1.6 |
2.0 |
32.4 |
2x120 |
12.4 |
1.6 |
2.1 |
35.4 |
2x150 |
13.8 |
1.8 |
2.2 |
39.2 |
2x185 |
15.3 |
2 |
2.4 |
43.3 |
2x240 |
17.5 |
2.2 |
2.5 |
48.9 |
2x300 |
19.5 |
2.4 |
2.7 |
54.0 |
2x400 |
22.6 |
2.6 |
2.9 |
61.5 |
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Overall Diameter (Approx.) |
mm^2 |
mm |
mm |
mm |
mm |
3x1.5 |
1.4 |
0.8 |
1.8 |
10.1 |
3x2.5 |
1.8 |
0.8 |
1.8 |
10.9 |
3x4 |
2.3 |
1 |
1.8 |
12.9 |
3x6 |
2.8 |
1 |
1.8 |
13.9 |
3x10 |
3.6 |
1 |
1.8 |
15.7 |
3x16 |
4.5 |
1 |
1.8 |
17.6 |
3x25 |
5.6 |
1.2 |
1.8 |
20.8 |
3x35 |
6.7 |
1.2 |
1.8 |
23.2 |
3x50 |
8 |
1.4 |
1.8 |
26.9 |
3x70 |
9.4 |
1.4 |
1.9 |
30.1 |
3x95 |
11 |
1.6 |
2.1 |
34.7 |
3x120 |
12.4 |
1.6 |
2.2 |
38.0 |
3x150 |
13.8 |
1.8 |
2.3 |
42.1 |
3x185 |
15.3 |
2 |
2.5 |
46.5 |
3x240 |
17.5 |
2.2 |
2.7 |
52.5 |
3x300 |
19.5 |
2.4 |
2.8 |
58.0 |
3x400 |
22.6 |
2.6 |
3.1 |
66.1 |
Three cores+1(unarmoured) |
|
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Overall Diameter (Approx.) |
mm^2 |
(3)mm |
(1)mm |
(3)mm |
(1)mm |
mm |
mm |
3x 16/10 |
4.5 |
3.6 |
1 |
1 |
1.8 |
19.0 |
3x 25/16 |
5.6 |
4.5 |
1.2 |
1 |
1.8 |
22.6 |
3x 35/16 |
6.7 |
4.5 |
1.2 |
1 |
1.8 |
25.3 |
3x 50/25 |
8.0 |
5.6 |
1.4 |
1.2 |
1.9 |
29.6 |
3x 70/35 |
9.4 |
6.7 |
1.4 |
1.2 |
2.0 |
33.2 |
3x 95/50 |
11.0 |
8.0 |
1.6 |
1.4 |
2.2 |
38.4 |
3x120/70 |
12.4 |
9.4 |
1.6 |
1.4 |
2.3 |
42.0 |
3x150/70 |
13.8 |
9.4 |
1.8 |
1.4 |
2.5 |
46.6 |
3x185/95 |
15.3 |
11.0 |
2 |
1.6 |
2.6 |
51.6 |
3x240/120 |
17.5 |
12.4 |
2.2 |
1.6 |
2.9 |
58.3 |
3x300/150 |
19.5 |
13.8 |
2.4 |
1.8 |
3.1 |
64.5 |
3x400/185 |
22.6 |
15.3 |
2.6 |
2 |
3.3 |
73.5 |
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Overall Diameter (Approx.) |
mm^2 |
mm |
mm |
mm |
mm |
4x1.5 |
1.4 |
0.8 |
1.8 |
10.8 |
4x2.5 |
1.8 |
0.8 |
1.8 |
11.8 |
4x4 |
2.3 |
1 |
1.8 |
14.0 |
4x6 |
2.8 |
1 |
1.8 |
15.2 |
4x10 |
3.6 |
1 |
1.8 |
17.1 |
4x16 |
4.5 |
1 |
1.8 |
19.3 |
4x25 |
5.6 |
1.2 |
1.8 |
22.9 |
4x35 |
6.7 |
1.2 |
1.8 |
25.6 |
4x50 |
8 |
1.4 |
1.9 |
29.9 |
4x70 |
9.4 |
1.4 |
2.0 |
33.5 |
4x95 |
11 |
1.6 |
2.2 |
38.7 |
4x120 |
12.4 |
1.6 |
2.3 |
42.3 |
4x150 |
13.8 |
1.8 |
2.5 |
46.9 |
4x185 |
15.3 |
2 |
2.6 |
51.9 |
4x240 |
17.5 |
2.2 |
2.9 |
58.6 |
4x300 |
19.5 |
2.4 |
3.1 |
64.8 |
4x400 |
22.6 |
2.6 |
3.3 |
73.8 |
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation Thickness |
Nominal Sheath Thickness |
Overall Diameter (Approx.) |
mm^2 |
mm |
mm |
mm |
mm |
5x1.5 |
1.4 |
0.8 |
1.8 |
11.7 |
7x1.5 |
1.4 |
0.8 |
1.8 |
12.6 |
10x1.5 |
1.4 |
0.8 |
1.8 |
15.6 |
12x1.5 |
1.4 |
0.8 |
1.8 |
16.1 |
14x1.5 |
1.4 |
0.8 |
1.8 |
16.8 |
19x1.5 |
1.4 |
0.8 |
1.8 |
18.6 |
21x1.5 |
1.4 |
0.8 |
1.8 |
19.5 |
24x1.5 |
1.4 |
0.8 |
1.8 |
21.6 |
30x1.5 |
1.4 |
0.8 |
1.8 |
22.8 |
40x1.5 |
1.4 |
0.8 |
1.8 |
27.7 |
48x1.5 |
1.4 |
0.8 |
1.9 |
28.2 |
61x1.5 |
1.4 |
0.8 |
1.9 |
30.9 |
5x2.5 |
1.8 |
0.8 |
1.8 |
12.8 |
7x2.5 |
1.8 |
0.8 |
1.8 |
13.8 |
10x2.5 |
1.8 |
0.8 |
1.8 |
17.2 |
12x2.5 |
1.8 |
0.8 |
1.8 |
17.7 |
14x2.5 |
1.8 |
0.8 |
1.8 |
18.6 |
19x2.5 |
1.8 |
0.8 |
1.8 |
20.6 |
21x2.5 |
1.8 |
0.8 |
1.8 |
21.6 |
24x2.5 |
1.8 |
0.8 |
1.8 |
24.0 |
30x2.5 |
1.8 |
0.8 |
1.8 |
25.4 |
40x2.5 |
1.8 |
0.8 |
2.0 |
31.1 |
48x2.5 |
1.8 |
0.8 |
2.0 |
31.7 |
61x2.5 |
1.8 |
0.8 |
2.1 |
34.7 |
Single core( aluminum wire armoured) |
|
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm^2 |
mm |
mm |
mm |
mm |
mm |
mm |
1x4 |
2.3 |
1 |
1.0 |
0.8 |
1.8 |
11.5 |
1x6 |
2.8 |
1 |
1.0 |
0.8 |
1.8 |
12.0 |
1x10 |
3.6 |
1 |
1.0 |
0.8 |
1.8 |
12.8 |
1x16 |
4.5 |
1 |
1.0 |
0.8 |
1.8 |
13.7 |
1x25 |
5.6 |
1.2 |
1.0 |
0.8 |
1.8 |
15.2 |
1x35 |
6.7 |
1.2 |
1.0 |
1.25 |
1.8 |
17.2 |
1x50 |
8.0 |
1.4 |
1.0 |
1.25 |
1.8 |
18.9 |
1x70 |
9.4 |
1.4 |
1.0 |
1.25 |
1.8 |
20.3 |
1x95 |
11.0 |
1.6 |
1.0 |
1.6 |
1.8 |
23.0 |
1x120 |
12.4 |
1.6 |
1.0 |
1.6 |
1.8 |
24.4 |
1x150 |
13.8 |
1.8 |
1.0 |
1.6 |
1.8 |
26.2 |
1x185 |
15.3 |
2 |
1.0 |
1.6 |
1.9 |
28.2 |
1x240 |
17.5 |
2.2 |
1.0 |
1.6 |
1.9 |
31.0 |
1x300 |
19.5 |
2.4 |
1.0 |
2.0 |
2.1 |
34.4 |
1x400 |
22.6 |
2.6 |
1.2 |
2.0 |
2.2 |
38.6 |
1x500 |
25.2 |
2.8 |
1.2 |
2.0 |
2.3 |
41.8 |
1x630 |
28.3 |
2.8 |
1.2 |
2.5 |
2.4 |
46.2 |
Two cores(Galvanized steel wire armoured) |
|
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm^2 |
mm |
mm |
mm |
mm |
mm |
mm |
2x2.5 |
1.8 |
0.8 |
1.0 |
0.8 |
1.8 |
14.0 |
2x4 |
2.3 |
1 |
1.0 |
1.25 |
1.8 |
16.7 |
2x6 |
2.8 |
1 |
1.0 |
1.25 |
1.8 |
17.7 |
2x10 |
3.6 |
1 |
1.0 |
1.25 |
1.8 |
19.3 |
2x16 |
4.5 |
1 |
1.0 |
1.25 |
1.8 |
21.1 |
2x25 |
5.6 |
1.2 |
1.0 |
1.6 |
1.8 |
24.8 |
2x35 |
6.7 |
1.2 |
1.0 |
1.6 |
1.8 |
27.0 |
2x50 |
8 |
1.4 |
1.0 |
1.6 |
1.9 |
30.7 |
2x70 |
9.4 |
1.4 |
1.0 |
2.0 |
2.1 |
34.5 |
2x95 |
11 |
1.6 |
1.2 |
2.0 |
2.2 |
39.2 |
2x120 |
12.4 |
1.6 |
1.2 |
2.0 |
2.3 |
42.2 |
2x150 |
13.8 |
1.8 |
1.2 |
2.5 |
2.5 |
47.2 |
2x185 |
15.3 |
2 |
1.4 |
2.5 |
2.6 |
51.6 |
2x240 |
17.5 |
2.2 |
1.4 |
2.5 |
2.8 |
57.2 |
2x300 |
19.5 |
2.4 |
1.6 |
2.5 |
3.0 |
62.8 |
2x400 |
22.6 |
2.6 |
1.6 |
2.5 |
3.2 |
70.3 |
Three cores(Galvanized steel wire armoured) |
|
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm^2 |
mm |
mm |
mm |
mm |
mm |
mm |
3x2.5 |
1.8 |
0.8 |
1.0 |
0.8 |
1.8 |
14.5 |
3x4 |
2.3 |
1 |
1.0 |
1.25 |
1.8 |
17.4 |
3x6 |
2.8 |
1 |
1.0 |
1.25 |
1.8 |
18.4 |
3x10 |
3.6 |
1 |
1.0 |
1.25 |
1.8 |
20.2 |
3x16 |
4.5 |
1 |
1.0 |
1.6 |
1.8 |
22.8 |
3x25 |
5.6 |
1.2 |
1.0 |
1.6 |
1.8 |
26.0 |
3x35 |
6.7 |
1.2 |
1.0 |
1.6 |
1.9 |
28.5 |
3x50 |
8.0 |
1.4 |
1.0 |
2 |
2.0 |
33.3 |
3x70 |
9.4 |
1.4 |
1.2 |
2 |
2.1 |
37.0 |
3x95 |
11.0 |
1.6 |
1.2 |
2 |
2.3 |
41.6 |
3x120 |
12.4 |
1.6 |
1.2 |
2.5 |
2.4 |
45.9 |
3x150 |
13.8 |
1.8 |
1.4 |
2.5 |
2.6 |
50.4 |
3x185 |
15.3 |
2 |
1.4 |
2.5 |
2.7 |
54.8 |
3x240 |
17.5 |
2.2 |
1.5 |
2.5 |
2.9 |
61.2 |
3x300 |
19.5 |
2.4 |
1.6 |
2.5 |
3.1 |
66.8 |
3x400 |
22.6 |
2.8 |
1.6 |
3.15 |
3.4 |
76.7 |
3x500 |
25.2 |
2.8 |
1.8 |
3.15 |
3.7 |
83.6 |
Three cores+1(Galvanized steel wire armoured) |
|
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm^2 |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
mm |
3x10/6 |
3.6 |
2.8 |
1 |
1 |
1 |
1.25 |
1.8 |
21.9 |
3x16/10 |
4.5 |
3.6 |
1 |
1 |
1 |
1.6 |
1.8 |
24.2 |
3x25/16 |
5.6 |
4.5 |
1.2 |
1 |
1 |
1.6 |
1.8 |
27.9 |
3x35/16 |
6.7 |
4.5 |
1.2 |
1 |
1 |
1.6 |
1.9 |
30.8 |
3x50/25 |
8.0 |
5.6 |
1.4 |
1.2 |
1 |
2.0 |
2.0 |
36.4 |
3x70/35 |
9.4 |
6.7 |
1.4 |
1.2 |
1.2 |
2.0 |
2.1 |
40.1 |
3x95/50 |
11.0 |
8.0 |
1.6 |
1.4 |
1.2 |
2.5 |
2.3 |
46.3 |
3x120/70 |
12.4 |
9.4 |
1.6 |
1.4 |
1.4 |
2.5 |
2.4 |
50.3 |
3x150/70 |
13.8 |
9.4 |
1.8 |
1.4 |
1.4 |
2.5 |
2.6 |
55.0 |
3x185/95 |
15.3 |
11.0 |
2 |
1.6 |
1.4 |
2.5 |
2.7 |
60.3 |
3x240/120 |
17.5 |
12.4 |
2.2 |
1.6 |
1.6 |
2.5 |
2.9 |
67.0 |
3x300/150 |
19.5 |
13.8 |
2.4 |
1.8 |
1.6 |
3.15 |
3.1 |
74.6 |
3x400/185 |
22.6 |
15.3 |
2.6 |
2 |
1.8 |
3.15 |
3.4 |
84.1 |
3x500/240 |
25.2 |
17.5 |
2.8 |
2.2 |
2 |
3.15 |
3.7 |
91.8 |
Four cores(Galvanized steel wire armoured) |
|
Nominal Cross Section |
Diameter of Conductor (Approx.) |
Nominal Insulation thickness |
Nominal Inner Covering thickness |
Nominal Steel Wire dia. |
Nominal Sheath thickness |
Overall Diameter (Approx.) |
mm^2 |
mm |
mm |
mm |
mm |
mm |
mm |
4x4 |
2.3 |
1 |
1 |
1.25 |
1.8 |
18.5 |
4x6 |
2.8 |
1 |
1 |
1.25 |
1.8 |
19.7 |
4x10 |
3.6 |
1 |
1 |
1.25 |
1.8 |
22.3 |
4x16 |
4.5 |
1 |
1 |
1.6 |
1.8 |
24.5 |
4x25 |
5.6 |
1.2 |
1 |
1.6 |
1.9 |
28.2 |
4x35 |
6.7 |
1.2 |
1 |
1.6 |
2.0 |
31.1 |
4x50 |
8.0 |
1.4 |
1 |
2.0 |
2.1 |
36.7 |
4x70 |
9.4 |
1.4 |
1.2 |
2.0 |
2.3 |
40.4 |
4x95 |
11.0 |
1.6 |
1.2 |
2.5 |
2.5 |
46.6 |
4x120 |
12.4 |
1.6 |
1.4 |
2.5 |
2.6 |
50.6 |
4x150 |
13.8 |
1.8 |
1.4 |
2.5 |
2.7 |
55.3 |
4x185 |
15.3 |
2 |
1.4 |
2.5 |
2.9 |
60.6 |
4x240 |
17.5 |
2.2 |
1.6 |
2.5 |
3.1 |
67.3 |
4x300 |
19.5 |
2.4 |
1.6 |
3.15 |
3.4 |
74.9 |
4x400 |
22.6 |
2.6 |
1.8 |
3.15 |
3.7 |
84.4 |
4x500 |
25.2 |
2.8 |
2 |
3.15 |
3.9 |
92.1 |







1. Are you a manufacturer or trading company?
We are a professional manufacturer. We can control your order from the first begining to the last.
Welcome to visit us. We'll pick you up in SHIJIAZHUANG.
2. How can I get a sample to test your quality?
The samples are free for you. New clients are expected to pay for the courier cost.
3. What's your Minimum Order Quantity?
Normally 100m. However, the cable is very heavy.
You'd better order a suitable quantity to avoid the high freight.
Sea transportation is the best option.
4. Can I get a discount?
It depends on your quantity, We can make a discount and afford the freight. Pls kindly contact us for further discussion.
5. Does your company accept OEM production?
Yes, could print your company name, we even custom the quality card to promote your company.